SUN-14/15/16/18/20K-SG05LP3-EU-SM2

Deye Hybrid On Off Grid Inverter Available in Nigeria

Three Phase Hybrid Inverter | 14-20kW | 2 MPPT | LV Battery Supported

  • 100% unbalanced output, max. output up to 50% rated power for each phase
  • AC couple to retrofit existing solar system
  • Max. 10 pcs parallel for on-grid and off-gridoperation; support multiple batteries parallel
  • Max. charging/discharging current of 350A
  • Support storing energy from diesel generator
  • 48V low voltage battery, transformer isolation design
  • 6 time periods for battery charging/discharging
ModellSUN-14K-SG05LP3
-EU-SM2
SUN-15K-SG05LP3
-EU-SM2
SUN-16K-SG05LP3
-EU-SM2
SUN-18K-SG05LP3
-EU-SM2
SUN-20K-SG05LP3
-EU-SM2
Battery Input Data
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range (V)40-60
Max. Charging/Discharging Current (A)260280300330350
Charging Strategy forLi-ion BatterySelf-adaption to BMS
Number of Battery Input2
PV String Input Data
Max. PV Access Power (W)2800030000320003600040000
Max. PV Input Power (W)2240024000256002880032000
Max. PV Input Voltage (V)800
Start-up Voltage (V)160
MPPT Voltage Range (V)160-650
Rated PV Input Voltage (V)550
Max. Operating PV Input Current (A)36+36
Max. Input Short-Circuit Current (A)54+54
No.of MPPT Trackers/
No.of Strings MPP Tracker
2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W)1400015000160001800020000
Max. AC Input/Output Apparent Power (VA)1540016500176001980022000
Rated AC Input/Output Current (A)21.3/20.322.8/21.824.3/23.227.3/26.130.4/29
Max. AC Input/Output Current (A)23.4/22.425/2426.7/25.630/28.733.4/31.9
Max. Continuous AC Passthrough (grid to load) (A)70
Peak Power (off-grid) (W)2 times of rated power, 10s
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Rated Input/Output Voltage220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE
Rated Input/Output Grid Frequency/Range(Hz)50/45-55, 60/55-65
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Component of Grid<0.5% In
Efficiency
Max. Efficiency97.6%
Euro Efficiency97.0%
MPPTEfficiency>99%
Equipment Protection
IntegratedDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
LCD/LED DisplayLCD
Communication InterfaceWIFI, RS485, CAN
General Data
Operating Temperature Range (℃)-40 to +60℃, >45℃ Derating
Permissible Ambient Humidity0-100%
Permissible Altitude3000m
Noise(dB)<60
Ingress Protection(IP) RatingIP 65
Inverter TopologyNon-Isolated (solar), Isolated (battery)
Over Voltage CategoryOVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm)456×750×268.5 (Excluding Connectors and Brackets)
Weight (kg)51.9
Type of CoolingIntelligent Air Cooling
Warranty5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid RegulationIEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105
Safety / EMC StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

ModelSUN-3K-SG05
LP3-EU-SM2
SUN-4K-SG05
LP3-EU-SM2
SUN-5K-SG05
LP3-EU-SM2
SUN-6K-SG05
LP3-EU-SM2
SUN-8K-SG05
LP3-EU-SM2
SUN-10K-SG05
LP3-EU-SM2
SUN-12K-SG05
LP3-EU-SM2
Battery Input Data
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range (V)40-60
Max. Charging/Discharging Current (A)7095120135190210240
Charging Strategy forLi-ion BatterySelf-adaption to BMS
Number of Battery Input1
PV String Input Data
Max. PV Access Power (W)600080001000012000160002000024000
Max. PV Input Power (W)4500640080009600128001600019200
Max. PV Input Voltage (V)800
Start-up Voltage (V)160
MPPT Voltage Range (V)200-650
Rated PV Input Voltage (V)550
Max. Operating PV Input Current (A)20+2026+26
Max. Input Short-Circuit Current (A)30+3039+39
No. of MPP Trackers/No. of Strings MPP Tracker2/1+12/2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W)300040005000600080001000012000
Max. AC Input/Output Apparent Power (VA)330044005500660088001100013200
Rated AC Input/Output Current (A)4.6/4.46.1/5.87.6/7.39.1/8.712.2/11.615.2/14.518.2/17.4
Max. AC Input/Output Current (A)5/4.86.7/6.48.4/810/9.613.4/12.816.7/1620/19.2
Max. Continuous AC Passthrough (grid to load) (A)45
Peak Power (off-grid) (W)2 times of rated power, 10s
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Rated Input/Output Voltage220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE
Rated Input/Output Grid Frequency/Range(Hz)50/45-55, 60/55-65
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Injection Current<0.5% In
Efficiency
Max. Efficiency97.6%
Euro Efficiency97.0%
MPPT Efficiency>99%
Equipment Protection
IntegratedDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
LCD/LED DisplayLCD
Communication InterfaceWIFI,RS485,CAN
General Data
Operating Temperature Range (℃)-40 to +60℃, >45℃ Derating
Permissible Ambient Humidity0-100%
Permissible Altitude3000m
Noise (dB)≤55
Ingress Protection(IP) RatingIP 65
Inverter TopologyNon-Isolated (solar), Isolated (battery)
Over Voltage CategoryOVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm)386×660×250 (Excluding Connectors and Brackets)
Weight (kg)35.2
Type of CoolingIntelligent Air Cooling
Warranty5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid RegulationIEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25,G99,VDE-AR-N 4105
Safety / EMC StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2